{"id":1199,"date":"2016-09-21T16:50:17","date_gmt":"2016-09-21T14:50:17","guid":{"rendered":"http:\/\/www.htflux.com\/en\/?page_id=1199"},"modified":"2016-10-12T16:38:03","modified_gmt":"2016-10-12T14:38:03","slug":"psi-g-ground-contact-calculations","status":"publish","type":"page","link":"https:\/\/www.htflux.com\/en\/documentation\/psi-g-ground-contact-calculations\/","title":{"rendered":"\u03a8g &#8211; ground contact calculations"},"content":{"rendered":"<h1>\u03a8g &#8211; ground contact calculations<\/h1>\n<p>The following pages will show you how to calculate the so called \u03a8g values. These linear thermal transmittances values are used to precisely calculate to energy loss to the ground. As always the calculation of the \u03a8 value is necessary to turn the simplified (surface based) U-value calculation of the buildings energy loss into a precise calculation. Omitting the calculation of these thermal bridging coefficients can therefore lead to significantly false energy calculations.<\/p>\n<p>It is important to understand that these \u03a8g values for the \u201cground-floor junction\u201d do not just describe the additional heat loss of the actual slab edge. \u03a8g values are used to correct the overall error made by using the simplified U-value calculations for the ground floor. Therefor it is important to note that a certain width of the floor slab has to be used for the simulation of the floor slab or basement. The \u03a8g value will only be valid for this actual width.<\/p>\n<p>Unfortunately, various methods are used to carry out the \u03a8g calculation. Since HTflux is used world-wide and by various types of experts (building scientists, passive house planers, architects, \u2026) it covers all calculation methods.<\/p>\n<p>Depending on your calculation requirements you will have to pick the method suitable for your needs. Here is an overview of the main calculation methods (click on the titles for the detailed description):<\/p>\n<h3><a title=\"\u03a8g \u2013 slab on grade (ISO)\" href=\"http:\/\/www.htflux.com\/en\/documentation\/psi-g-ground-contact-calculations\/psi-g-slab-on-grade\/\">\u03a8g-calculation with slab on or near the grade level according to ISO 10211 and ISO 13370<\/a><\/h3>\n<p>The method involves the calculation of a U<sub>g<\/sub>-value for the floor slab according to ISO13370. In HTflux the <em>U-value<\/em> and <em>Heatflux-tool<\/em> is used for the measurements and the <em>PSIg-tool<\/em> is being applied for the actual calculation of the \u03a8g value.<\/p>\n<h3>\u03a8g-calculation with slab on or near the grade level according to ISO 10211 &#8211; Option B<\/h3>\n<p>The so called &#8220;option B&#8221; of ISO 10211 allows a simplified calculation of a \u03a8g value with the actual use of the Ug value defined in ISO 13370. In HTflux the <em>U-value<\/em> and <em>Heatflux-tool<\/em> is used for the necessary measurements and the <em>PSIg-tool<\/em> is being applied for the calculation of the \u03a8g value.<\/p>\n<h3><a title=\"\u03a8g \u2013 slab below grade (ISO)\" href=\"http:\/\/www.htflux.com\/en\/documentation\/psi-g-ground-contact-calculations\/psi-g-slab-below-grade\/\">\u03a8g-calculation with slab below grade level (or heated basement) using ISO 10211 and ISO 13370<\/a><\/h3>\n<p>This option has to be used when the slab is significantly below ground level. Similar to the U<sub>g<\/sub>-value used for the floor slab a special U<sub>bw<\/sub>-value has to be calculated for the wall below ground level. In HTflux the <em>U-value<\/em> and <em>Heatflux-tool<\/em> is used for the measurements and the <em>PSIg-tool<\/em> is being applied for the calculation.<\/p>\n<h3>\u03a8g-calculation using boundary conditions as ground (ENEV)<\/h3>\n<p>This method is often allowed as a simplified calculation option. Like in the German ENVE calculations. The calculation with HTflux is very easy as only the automatic <em>PSI-tool<\/em> is required.<\/p>\n<h3>\u03a8g-calculation using a soil block and boundary condition as ground<\/h3>\n<p>Apart from the ISO calculation this method is also used by some passive house designers. The calculation with HTflux is very easy as only the automatic <em>PSI-tool<\/em> is required for this purpose.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u03a8g &#8211; ground contact calculations The following pages will show you how to calculate the so called \u03a8g values. These linear thermal transmittances values are used to precisely calculate to energy loss to the ground. As always the calculation of the \u03a8 value is necessary to turn the simplified (surface based) U-value calculation of the [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":423,"menu_order":0,"comment_status":"open","ping_status":"open","template":"pageTemp-userGuide_NEW.php","meta":{"footnotes":""},"class_list":["post-1199","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.htflux.com\/en\/wp-json\/wp\/v2\/pages\/1199","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.htflux.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.htflux.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.htflux.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.htflux.com\/en\/wp-json\/wp\/v2\/comments?post=1199"}],"version-history":[{"count":15,"href":"https:\/\/www.htflux.com\/en\/wp-json\/wp\/v2\/pages\/1199\/revisions"}],"predecessor-version":[{"id":1277,"href":"https:\/\/www.htflux.com\/en\/wp-json\/wp\/v2\/pages\/1199\/revisions\/1277"}],"up":[{"embeddable":true,"href":"https:\/\/www.htflux.com\/en\/wp-json\/wp\/v2\/pages\/423"}],"wp:attachment":[{"href":"https:\/\/www.htflux.com\/en\/wp-json\/wp\/v2\/media?parent=1199"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}